Steel fiber chopped good quality 13mm cheap
Technical requirements for ground construction of steel fiber reinforced concrete industrial buildings
General engineering mix
Steel fiber content (%) | sand ratio (%) |  water cement ratio | Collapsbillity (cm) | dosage per unit (Kg/cubic) |
steel fibre | concrete | Â gravel | sand | water |
1-1.2 | 40 | 0.45 | 3-5 | 78 | 450 | 1233 | 819 | 180 |
Crucial engineering mix
Steel fiber content (%) | sand ratio (%) |  water cement ratio | Collapsbillity (cm) | dosage per unit (Kg/cubic) |
steel fibre | concrete | Â gravel | sand | water |
1.5-1.8 | 46 | 0.45 | 3-5 | 120 | 450 | 1210 | 1035 | 200 |